Program

VarSpd1

Set ReefCres

VarSpd2

Set Night

VarSpd3

Set Feed

VarSpd4

Set Slow

SndAlm_I6

Set OFF 
  If Temp > 82.0 Then ON 
  If Temp < 75.0 Then ON

SndWrn_I7

Set OFF

EmailAlm_I5

Set OFF 
  If Temp > 81.5 Then ON 
  If Tmpx5 > 84.0 Then ON 
  If Temp < 76.0 Then ON 
  If Outlet DispHigh = ON Then ON 
  If Outlet SumpHigh = ON Then ON 
  If Outlet SuperLow = ON Then ON 
  If Outlet WaterFloor = ON Then ON 
  If Power EB8_3 Off 000 Then ON 
  If Power EB8_4 Off 000 Then ON 
  If Outlet RODILow = ON Then ON 
  Defer 460:00 Then ON 
  If Outlet SkimCupFull = ON Then ON 
  Defer 120:00 Then ON 
  If pH < 07.50 Then ON 
  If pH > 08.50 Then ON 
  If FeedA 000 Then OFF 
  If FeedB 000 Then OFF 
  If FeedC 000 Then OFF

MHLight

Fallback OFF 
  Set OFF 
  If Time 17:00 to 23:00 Then ON 
  If DoW ---W--- Then OFF 
  If Temp > 81.5 Then OFF 
  If Temp < 74.0 Then OFF 
  Min Time 030:00 Then OFF

SupLight

Fallback OFF 
  Set OFF 
  If Time 16:30 to 23:30 Then ON 
  If Temp > 82.0 Then OFF 
  Min Time 005:00 Then OFF

StandLight

Fallback OFF 
  Set OFF 
  If Outlet DoorSW = ON Then ON 
  If FeedB 000 Then ON 
  If FeedD 000 Then ON 
  If Outlet WaterFloor = ON Then ON

TwoPTDose

Fallback OFF 
  Set OFF 
  If Time 19:00 to 20:00 Then ON 
  If pH > 08.30 Then OFF

RetPump

Fallback ON 
  Set ON 
  If Outlet DispHigh = ON Then OFF 
  If FeedA 000 Then OFF 
  If FeedD 000 Then OFF 
  If FeedC 000 Then OFF 
  If Outlet WaterFloor = ON Then OFF 
  If Outlet SuperLow = ON Then OFF 
  Defer 000:05 Then OFF 
  If Outlet Feed_Start = ON Then OFF 
  Defer 002:00 Then ON

RefLight

Fallback OFF 
  Set OFF 
  If Time 00:00 to 12:00 Then ON 
  Min Time 030:00 Then OFF 
  If Temp > 82.0 Then OFF 
  If Temp < 73.0 Then OFF

Skimmer

Fallback OFF 
  Set ON 
  If Outlet TopoffHigh = ON Then OFF 
  Defer 000:10 Then ON 
  If FeedA 002 Then OFF 
  If FeedB 000 Then OFF 
  If FeedD 002 Then OFF 
  If FeedC 002 Then OFF 
  If Outlet WaterFloor = ON Then OFF 
  If Outlet SkimCupFull = ON Then OFF 
  Defer 000:05 Then OFF 
  If Outlet SuperLow = ON Then OFF 
  Defer 000:05 Then OFF

KalkMX

Fallback OFF 
  OSC 120:00/001:00/000:00 Then ON

Vortech_6_1

Fallback ReefCres 
  If Time 12:00 to 00:00 Then ReefCres 
  If Time 00:01 to 11:59 Then Night 
  If FeedA 000 Then Feed 
  If FeedD 000 Then OFF 
  If FeedC 000 Then Nutrient 
  If Outlet Feed_Start = ON Then OFF 
  Defer 002:00 Then ON

TopoffLow

If Switch1 OPEN Then ON 
  If Switch1 CLOSED Then OFF

TopoffHigh

If Switch2 OPEN Then ON 
  If Switch2 CLOSED Then OFF

SuperLow

If Switch3 OPEN Then OFF 
  If Switch3 CLOSED Then ON

DispHigh

If Switch4 OPEN Then ON 
  If Switch4 CLOSED Then OFF

DoorSW

If Switch5 OPEN Then OFF 
  If Switch5 CLOSED Then ON

WaterFloor

If Switch6 OPEN Then OFF 
  If Switch6 CLOSED Then ON

RODILow

If Switchx5_5 OPEN Then ON 
  If Switchx5_5 CLOSED Then OFF

RODIHigh

If Switchx5_4 OPEN Then OFF 
  If Switchx5_4 CLOSED Then ON

RODIFill

Fallback OFF 
  If Outlet RODI_Start = ON Then ON 
  Defer 000:05 Then ON 
  If Outlet RODIHigh = ON Then OFF 
  Defer 000:05 Then OFF 
  If Outlet RODI_Start = ON Then ON 
  Defer 000:05 Then ON

Heat2

Fallback OFF 
  If Temp < 78.0 Then ON 
  If Temp > 78.5 Then OFF 
  Min Time 005:00 Then OFF 
  If FeedB 000 Then OFF 
  If FeedD 000 Then OFF

Heat1

Fallback OFF 
  If Temp < 78.0 Then ON 
  If Temp > 78.5 Then OFF 
  Min Time 005:00 Then OFF 
  If FeedB 000 Then OFF 
  If FeedD 000 Then OFF

Topoff

Fallback OFF 
  If Outlet TopoffLow = ON Then ON 
  Defer 000:20 Then ON 
  If Outlet TopoffLow = OFF Then OFF 
  Defer 001:00 Then OFF 
  If FeedA 000 Then OFF 
  If FeedB 000 Then OFF 
  If FeedD 000 Then OFF 
  If Outlet TopoffHigh = ON Then OFF 
  If Outlet RODILow = ON Then OFF

FanSump

Fallback OFF 
  Set OFF 
  OSC 059:00/001:00/000:00 Then ON 
  If Temp > 78.8 Then ON 
  If Temp < 78.6 Then OFF

Feeder

Fallback OFF 
  Set OFF 
  If Outlet Feed_Start = ON Then ON 
  Defer 000:30 Then ON

FanLight

Fallback ON 
  Set OFF 
  OSC 055:00/005:00/000:00 Then ON 
  If Temp > 79.0 Then ON 
  If Temp < 78.8 Then OFF 
  If Outlet MHLight = ON Then ON

AudAlarm

Fallback OFF 
  Set OFF 
  If Temp > 82.0 Then ON 
  If Temp < 75.0 Then ON 
  If pH > 08.50 Then ON 
  Defer 000:05 Then ON 
  If pH < 07.60 Then ON 
  Defer 000:05 Then ON 
  If Outlet DispHigh = ON Then ON 
  Defer 000:05 Then ON 
  If Outlet SumpHigh = ON Then ON 
  Defer 000:05 Then ON 
  If Outlet SuperLow = ON Then ON 
  If Outlet WaterFloor = ON Then ON 
  If FeedA 000 Then OFF 
  If FeedD 000 Then OFF

LunarSim

If Moon 000/000 Then ON

Vortech_6_2

Fallback ReefCres 
  If Time 12:00 to 00:00 Then ReefCres 
  If Time 00:01 to 11:59 Then Night 
  If FeedA 000 Then Feed 
  If FeedD 000 Then OFF 
  If FeedC 000 Then Nutrient 
  If Outlet Feed_Start = ON Then OFF 
  Defer 002:00 Then ON

SkimCupFull

If Switchx5_3 OPEN Then OFF 
  If Switchx5_3 CLOSED Then ON

DC_OK

If Switchx5_2 OPEN Then OFF 
  If Switchx5_2 CLOSED Then ON

SumpHigh

If Switchx5_6 OPEN Then ON 
  If Switchx5_6 CLOSED Then OFF

RODI_Start

If Switchx5_1 CLOSED Then OFF 
  If Switchx5_1 OPEN Then ON

Feed_Start

Fallback OFF 
  Set OFF 
  If Time 19:00 to 19:01 Then ON 
  If DoW -M-W-FS Then OFF

Virtural_Not

Fallback OFF 
  Set OFF

Virtural_Not

Fallback OFF 
  Set OFF

Virtural_Not

Fallback OFF 
  Set OFF

X10_A1

Fallback OFF 
  Set OFF

X10_A2

Fallback OFF 
  Set OFF

X10_A3

Fallback OFF 
  Set OFF

X10_A4

Fallback OFF 
  Set OFF